LIGHTEST TANKS FOR THE PRICE
Specifications
General Specifications:
  • Type 3 Tank
  • 6,000 PSI/414 bar operating pressure
  • 500,000 cycles between 2,500 and 5,500 PSI/172 and 379 bar
  • 22,500 PSI/1,550 bar burst testing, minimum burst pressure: 18,600 PSI / 1,282 bar
  • 1-7/8 – 24 SAE Female outlet port (other porting options available)
  • Poppet anti-extrusion valve
  • Bottom-load bladder: Buna-Nitrile (other materials available), 2,000 PSI/138 bar maximum nitrogen charge
  • Liner: 6061-T6 Aluminum
  • Optional: additional plastic liner for extended life
  • Shell: Carbon and epoxy
  • Failure mode: inherent leak-before-burst fatigue failure
  • Optimal temperature range: -120 to 185F (-84 to 85C)
Smart Tank Options:
  • Temperature sensors bonded to aluminum shell
  • Strain gauges monitor pressure cycles and spikes
  • Communication over CAN/WiFi/Bluetooth/other

Volume
(Gal)
Volume
(Liters)
Empty
Weight2
(Lbs)
Empty
Weight2
(Kg)
(L) Overall
Length1
(Inch)
(L) Overall
Length1
(Cm)
Bladder
Diameter
(Inch)
Bladder
Diameter
(Cm)
Price3
(US$)
10 37.85 100 45.36 37 93.98 10.00 25.4 contact us
15 56.78 120 54.43 51 129.54 10.00 25.4 contact us
20 75.71 140 63.50 66 167.64 10.00 25.4 contact us
22 83.28 150 68.04 74 187.96 10.00 25.4 contact us
25 94.64 160 72.57 81 205.74 10.00 25.4 contact us
30 113.56 170 77.11 96 243.84 10.00 25.4 contact us

1. Shell length does not include components
2. Weight is approximate
3. Quantity pricing available upon request


Voted
“Most Innovative New Technology”
at BusCon 2012


For more information contact us at 1-800-223-0740 ext. 104 or email

Bladder Materials

The Buna-Nitrile bladder and seal material is standard and suitable for most fluid power applications. Buna-N is readily available.

Mounting Position
Lightning Hybrids bladder accumulators can be readily installed vertically, or at any angle depending on the application. The fluid port must be at the bottom when the accumulator is installed vertically or horizontally. Specific orientations are preferable for applications listed below:
  • Energy Storage: vertical
  • Maintaining Constant Pressure: any position from vertical to horizontal
  • Pulsation Damping: any position from vertical to horizontal
  • Volume Compensation: any position from vertical to horizontal
SAFETY
Lightning Hybrids accumulators are:
  • Full peripheral impact and abuse testing including sidewall region
  • Tested to over 500,000 cycles, currently testing up to 3 million cycles
  • Burst tested to a safety factor greater than 3.4 times operating pressure
  • Inherent leak-before-burst fatigue failure mode
  • Safety shut-off valve
  • Compliant with applicable standards of USDOT CPPC (gas transport and fuel tank) and ANSI/CSA NGV2

Lightning Hybrids accumulators are made and assembled in the USA.